N2 - Sinks configure the surface networks for overland flow processes representations during 1D hydrodynamic modelling. The excessive number of sinks detected from high-resolution DEMs can boost 1D computational costs significantly. To pursue optimal sink numbers and their optimal spatial distribution, a Volume Ratio Sink Screening (VRSS) method was developed to screen for computationally important sinks, while compensating for volume losses from removed (unimportant) sinks, such that 1D hydrodynamic modelling yields faster computing times without significant loss of accuracy. In comparison with an existing geometry-based sink screening method, we validated this method by conducting sensitivity analyses for the proposed screening criteria in three Danish case areas of distinct topographies. Two iterative procedures were programmed to assess and compare their sink screening performances in terms of sink number reductions and volume loss reductions, and a volume loss solver was developed to quantify catchment-wide volume losses in the 1D surface network. Compared to a geometry-based sink screening method, the VRSS method performs more robustly and produces more efficient reductions in the number of sinks, as well as efficient reductions in volume losses.
AB - Sinks configure the surface networks for overland flow processes representations during 1D hydrodynamic modelling. The excessive number of sinks detected from high-resolution DEMs can boost 1D computational costs significantly. To pursue optimal sink numbers and their optimal spatial distribution, a Volume Ratio Sink Screening (VRSS) method was developed to screen for computationally important sinks, while compensating for volume losses from removed (unimportant) sinks, such that 1D hydrodynamic modelling yields faster computing times without significant loss of accuracy. In comparison with an existing geometry-based sink screening method, we validated this method by conducting sensitivity analyses for the proposed screening criteria in three Danish case areas of distinct topographies. Two iterative procedures were programmed to assess and compare their sink screening performances in terms of sink number reductions and volume loss reductions, and a volume loss solver was developed to quantify catchment-wide volume losses in the 1D surface network. Compared to a geometry-based sink screening method, the VRSS method performs more robustly and produces more efficient reductions in the number of sinks, as well as efficient reductions in volume losses.
KW - technology, engineering and IT
KW - 1D hydrodynamic modelling
KW - 1D surface network simplification
KW - sink screening methods
KW - urban flood modelling
KW - volume ratio sink screening method
U2 - 10.3390/w14060963
DO - 10.3390/w14060963
M3 - Journal article
SN - 2073-4441
VL - 14
JO - Water
JF - Water
IS - 6
ER -