T1 - Cost-Effective and Highly Scalable Typing of HLA Classes I and II Genes of up to 96 Individuals Using Nanopore Sequencing
AU - Pedersen, Frederikke Byron
AU - Hauge, Anne Werner
AU - Hansen, Jacob Flemming
AU - Andersen, Laura Studnitz
AU - Blomsterberg, Signe
AU - Bruunsgaard, Helle
N1 - Publisher Copyright: © 2025 The Author(s). HLA: Immune Response Genetics published by John Wiley & Sons Ltd.
PY - 2025/4
Y1 - 2025/4
N2 - HLA typing of large donor registries and biobanks as well as acute single patient/donor samples remains expensive, slow and logistically challenging, despite recent developments in the field. We have tested and validated a cost-effective, accurate and highly scalable method for typing specific genes in the HLA region. This enables HLA typing from 1 to 96 individuals simultaneously, using a targeted PCR and Native Barcoding kit from Oxford Nanopore Technologies. A primer set for seven HLA genes (HLA-A, -B, -C, -DRB1, -DQA1, -DQB1 and -DPB1) was developed to work in a multiplex PCR reaction. The resulting amplicons provide a possible four-field resolution of the HLA Class I genes and G-group resolution of the HLA Class II genes. The entire process, from DNA to HLA typing result, takes a total of 5.5–10.5 h depending on the number of samples processed simultaneously. Data analysis was conducted using NGSEngine-Turbo from GenDx (Utrecht, The Netherlands), with analysis time ranging from 1 to 5 min per sample. Samples from 96 Danish registered stem cell donors were typed using this method. One allele out of 1128 analysed alleles was inaccurately called homozygous, leading to an accuracy of 99.91%. The rapid turnaround, low cost and high accuracy make this new method highly relevant for HLA typing of large biobanks and donor registries, as well as for acute single samples. HLA typing can be obtained within 1 day, with a cost per sample of approximately €7 when 96 samples are sequenced simultaneously.
AB - HLA typing of large donor registries and biobanks as well as acute single patient/donor samples remains expensive, slow and logistically challenging, despite recent developments in the field. We have tested and validated a cost-effective, accurate and highly scalable method for typing specific genes in the HLA region. This enables HLA typing from 1 to 96 individuals simultaneously, using a targeted PCR and Native Barcoding kit from Oxford Nanopore Technologies. A primer set for seven HLA genes (HLA-A, -B, -C, -DRB1, -DQA1, -DQB1 and -DPB1) was developed to work in a multiplex PCR reaction. The resulting amplicons provide a possible four-field resolution of the HLA Class I genes and G-group resolution of the HLA Class II genes. The entire process, from DNA to HLA typing result, takes a total of 5.5–10.5 h depending on the number of samples processed simultaneously. Data analysis was conducted using NGSEngine-Turbo from GenDx (Utrecht, The Netherlands), with analysis time ranging from 1 to 5 min per sample. Samples from 96 Danish registered stem cell donors were typed using this method. One allele out of 1128 analysed alleles was inaccurately called homozygous, leading to an accuracy of 99.91%. The rapid turnaround, low cost and high accuracy make this new method highly relevant for HLA typing of large biobanks and donor registries, as well as for acute single samples. HLA typing can be obtained within 1 day, with a cost per sample of approximately €7 when 96 samples are sequenced simultaneously.
KW - cost-effective
KW - high-throughput
KW - HLA
KW - long-read sequencing
KW - nanopore
KW - native barcoding
UR - https://www.scopus.com/pages/publications/105003804582
U2 - 10.1111/tan.70164
DO - 10.1111/tan.70164
M3 - Journal article
C2 - 40270210
SN - 2059-2302
VL - 105
JO - HLA
JF - HLA
IS - 4
M1 - e70164
ER -