TY - JOUR
T1 - Interrater Reliability of Dynamic Muscle Testing After Breast Cancer Surgery in Women at High Risk of Lymphedema
T2 - To Improve Quality in Clinical Practice
AU - Korsholm-Rosfort, Tina
AU - Larsen, Simone
AU - Aagaard, Thomas
AU - Ammitzbøll, Gunn
AU - Dalton, Susanne O.
N1 - Funding Information: The authors wish to thank all the involved women from project LYCA, who extraordinarily participated in this study. We thank Merete Celano Wittenkamp, Charlotte Lanng, Ann Nielsen, and Herlev Hospital for the use of space and equipment outside opening hours. The authors would like to give a special thanks to The Danish Cancer Society Research Center for the collaboration. The author(s) received no financial support for the research, authorship, and/or publication of this article. Publisher Copyright: © The Author(s) 2020. Copyright: Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020
Y1 - 2020
N2 - Background: The purpose of this study is to determine the interrater reliability of dynamic muscle tests in the early rehabilitation phase in women after breast cancer surgery with axillary lymph node dissection (ALND) based on the “preventive intervention against lymphedema after breast cancer” (LYCA) randomised controlled trial. Methods: Fifteen women treated with breast cancer surgery including ALND were recruited from participants in the LYCA trial. In this interrater reliability study, women were tested in 4 dynamic muscle tests by 2 physiotherapists at a Capital Hospital in Denmark. Intraclass correlation coefficients (ICCs) with 95% confidence intervals (CIs) was used to assess the relative reliability between raters. A Bland-Altman plot and limits of agreement were calculated to describe the absolute reliability. Results: All 6 subtests displayed high interrater reliability. ICC values were: leg press 0.96 (95% CI = 0.87-0.99), elbow flexion (contralateral) 0.94 (0.83-0.98), elbow flexion (affected arm) 0.93 (0.80-0.98), elbow extension 0.80 (0.41-0.93), shoulder abduction (contralateral) 0.89 (0.68-0.96), and shoulder abduction (affected arm) 0.91 (0.74-0.97). Cumulated interrater reliability for the test battery was very high (ICC = 0.99, 95% CI = 0.990-1.0). The absolute reliability of this study was considered high, and the absence of large shifts between mean and the line of 0 difference suggest no systematic bias that could influence clinical interpretation. Conclusions: The dynamic muscle tests evaluated in this study had high interrater reliability and can be used reliably in women in the postoperative phase after breast cancer surgery with ALND.
AB - Background: The purpose of this study is to determine the interrater reliability of dynamic muscle tests in the early rehabilitation phase in women after breast cancer surgery with axillary lymph node dissection (ALND) based on the “preventive intervention against lymphedema after breast cancer” (LYCA) randomised controlled trial. Methods: Fifteen women treated with breast cancer surgery including ALND were recruited from participants in the LYCA trial. In this interrater reliability study, women were tested in 4 dynamic muscle tests by 2 physiotherapists at a Capital Hospital in Denmark. Intraclass correlation coefficients (ICCs) with 95% confidence intervals (CIs) was used to assess the relative reliability between raters. A Bland-Altman plot and limits of agreement were calculated to describe the absolute reliability. Results: All 6 subtests displayed high interrater reliability. ICC values were: leg press 0.96 (95% CI = 0.87-0.99), elbow flexion (contralateral) 0.94 (0.83-0.98), elbow flexion (affected arm) 0.93 (0.80-0.98), elbow extension 0.80 (0.41-0.93), shoulder abduction (contralateral) 0.89 (0.68-0.96), and shoulder abduction (affected arm) 0.91 (0.74-0.97). Cumulated interrater reliability for the test battery was very high (ICC = 0.99, 95% CI = 0.990-1.0). The absolute reliability of this study was considered high, and the absence of large shifts between mean and the line of 0 difference suggest no systematic bias that could influence clinical interpretation. Conclusions: The dynamic muscle tests evaluated in this study had high interrater reliability and can be used reliably in women in the postoperative phase after breast cancer surgery with ALND.
KW - breast cancer lymphedema
KW - breast neoplasms
KW - interrater reliability
KW - lymphedema
KW - neoplasms
KW - reproducibility of results
KW - resistance training
U2 - 10.1177/1534735420903801
DO - 10.1177/1534735420903801
M3 - Journal article
C2 - 32108545
SN - 1534-7354
VL - 19
JO - Integrative Cancer Therapies
JF - Integrative Cancer Therapies
ER -