TY - JOUR
T1 - Validity and Intrarater Reliability of the FysioMeter—Measuring Eccentric Knee Flexor Force During the Nordic Hamstring Exercise
AU - Støve, Morten Pallisgaard
AU - Kristensen, Mathias Kringelholt
AU - Nielsen, Jonas
AU - Madsen, Lea Dyhrberg
N1 - Publisher Copyright: © 2025 The Author(s). Published with license by Taylor & Francis Group, LLC.
PY - 2025
Y1 - 2025
N2 - Between limb strength, asymmetry is a leading risk factor for hamstring strain re-injury. However, few accurate testing methodologies are available in clinical settings. This study examined the validity and reliability of eccentric knee flexor torque measured with a novel Nordic Hamstring Device. Twenty-seven healthy participants were assessed in two sessions. Maximal eccentric knee flexion torque was measured by the Biodex system 4 and during the Nordic Hamstrings Exercise in the FysioMeter. A moderate correlation was found between the FysioMeter and the Biodex (rho 0.674). Limits of agreement showed a bias of −43.9 Nm, suggesting that the FysioMeter underestimated the knee flexor peak torque compared with the Biodex. The FysioMeter showed excellent test–retest reliability (ICC 0.964). In conclusion, the FysioMeter provided moderately valid measures of knee flexor peak torque and excellent test–retest reliability. The FysioMeter could be a valuable tool for guiding rehabilitation in settings where access to isokinetic dynamometry is limited.
AB - Between limb strength, asymmetry is a leading risk factor for hamstring strain re-injury. However, few accurate testing methodologies are available in clinical settings. This study examined the validity and reliability of eccentric knee flexor torque measured with a novel Nordic Hamstring Device. Twenty-seven healthy participants were assessed in two sessions. Maximal eccentric knee flexion torque was measured by the Biodex system 4 and during the Nordic Hamstrings Exercise in the FysioMeter. A moderate correlation was found between the FysioMeter and the Biodex (rho 0.674). Limits of agreement showed a bias of −43.9 Nm, suggesting that the FysioMeter underestimated the knee flexor peak torque compared with the Biodex. The FysioMeter showed excellent test–retest reliability (ICC 0.964). In conclusion, the FysioMeter provided moderately valid measures of knee flexor peak torque and excellent test–retest reliability. The FysioMeter could be a valuable tool for guiding rehabilitation in settings where access to isokinetic dynamometry is limited.
KW - Hamstring strain injury
KW - Nordic hamstring exercise
KW - eccentric hamstring strength
KW - reliability
KW - validity
UR - https://www.scopus.com/pages/publications/85216676252
U2 - 10.1080/1091367X.2025.2457154
DO - 10.1080/1091367X.2025.2457154
M3 - Journal article
SN - 1091-367X
VL - 29
SP - 294
EP - 303
JO - Measurement in Physical Education and Exercise Science
JF - Measurement in Physical Education and Exercise Science
IS - 3
ER -