TY - JOUR
T1 - Inter-tester reliability and agreement of the Cumulated Ambulation Score in acute stroke
T2 - The InTRO-CAS-stroke study
AU - Arens, Christian Hedelund
AU - Johnsen, Nicole Milwertz
AU - Milanesi, Manuela
AU - Weli, Ali
AU - Linnebjerg, Connie
AU - Christensen, Hanne
AU - Kristensen, Morten Tange
N1 - Publisher Copyright: © 2024
PY - 2024/5
Y1 - 2024/5
N2 - Title: Inter-Tester Reliability and Agreement of the Cumulated Ambulation Score in Stroke patients: The InTRO-CAS-stroke study Objective: To examine the inter-tester reliability of the total Cumulated Ambulation Score (CAS) and the three activities of the CAS, and to define limits for the smallest change in basic mobility that indicates a real change in patients with stroke. Methods: An intertester reliability study. Setting: Participants: 60 participants from a specialized stroke unit with a mean age of 69.10 ± 13.23 years. The CAS describes a patient's independency in three activities – (1) getting in and out of bed, (2) sit to stand from a chair, and (3) walking ability and was assessed by two independent physiotherapists at median day 3 poststroke. Each activity was assessed on a three-point ordinal scale from 0 (not able to) to 2 (independent). The cumulated score for each activity provides a total CAS from 0 to 6, with 6 indicating independent basic mobility. Relative and absolute reliability was evaluated using weighted kappa, the standard error of measurement (SEM) and minimal detectable change (MDC). Results: The weighted kappa for the total CAS score was 0.816 and ranged from 0.733 to 0.904 for the 3 CAS activities. The SEM and the MDC of the total CAS was 0.37 and 1.03 respectively. Conclusions: The intertester reliability of the CAS is almost perfect, and a change of 1 CAS point for the total CAS indicates a real change in basic mobility, at group level and for an individual patient with stroke Clinicaltrials.gov
AB - Title: Inter-Tester Reliability and Agreement of the Cumulated Ambulation Score in Stroke patients: The InTRO-CAS-stroke study Objective: To examine the inter-tester reliability of the total Cumulated Ambulation Score (CAS) and the three activities of the CAS, and to define limits for the smallest change in basic mobility that indicates a real change in patients with stroke. Methods: An intertester reliability study. Setting: Participants: 60 participants from a specialized stroke unit with a mean age of 69.10 ± 13.23 years. The CAS describes a patient's independency in three activities – (1) getting in and out of bed, (2) sit to stand from a chair, and (3) walking ability and was assessed by two independent physiotherapists at median day 3 poststroke. Each activity was assessed on a three-point ordinal scale from 0 (not able to) to 2 (independent). The cumulated score for each activity provides a total CAS from 0 to 6, with 6 indicating independent basic mobility. Relative and absolute reliability was evaluated using weighted kappa, the standard error of measurement (SEM) and minimal detectable change (MDC). Results: The weighted kappa for the total CAS score was 0.816 and ranged from 0.733 to 0.904 for the 3 CAS activities. The SEM and the MDC of the total CAS was 0.37 and 1.03 respectively. Conclusions: The intertester reliability of the CAS is almost perfect, and a change of 1 CAS point for the total CAS indicates a real change in basic mobility, at group level and for an individual patient with stroke Clinicaltrials.gov
KW - Agreement
KW - Cumulated ambulation score
KW - Reliability
KW - Stroke
UR - http://www.scopus.com/inward/record.url?scp=85186929427&partnerID=8YFLogxK
U2 - 10.1016/j.jstrokecerebrovasdis.2024.107630
DO - 10.1016/j.jstrokecerebrovasdis.2024.107630
M3 - Journal article
C2 - 38325673
SN - 1052-3057
VL - 33
JO - Journal of Stroke and Cerebrovascular Diseases
JF - Journal of Stroke and Cerebrovascular Diseases
IS - 5
M1 - 107630
ER -